Su carrito de compras está vacío
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 5722 visitantes online.
Productos
Información
Destacado
Inicio >> PHILIPS >> EM5E AA Manual de Servicio
 
 0 artículo(s) en Su carrito 

PHILIPS EM5E AA
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del PHILIPS EM5E AA Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages:

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
Service Modes, Error Codes and Fault Finding
diagram A6) will put the IC7700 in Standby mode (via tristate input pin 6). For more details, see chapter 9.

EM5E

5.

EN 33

5.8
5.8.1

Repair tips
Miscellaneous The relay you hear when you switch the set 'on' (from Standby or via the mains switch), is from the degaussing circuitry. It is not used for switching the Power Supply (as done in the MGchassis). Take care not to touch the �hot� heatsink while disconnecting the SSB, despite the fact that the mains cord is out of the mains socket. There can still be an annoying rest-voltage on the heatsink for a short while. This, because the discharge resistors 3502 and 3503 (on the LSP between hot and cold part) are not stuffed for Europe. Instead, discharge resistors 3066 and 3057 on the Mains Switch panel are used, but because they are located before the Mains switch, they only discharge when this switch is �on�. Advice: when you remove the SSB, disconnect the Mains cord, but keep the Mains Switch �on�. Do not try to measure on the SSB side, which is facing the �hot� heatsink. This is dangerous. Most service test points are guided to the �tuner� side and are indicated by the �service� printing. Where the circuitry was too �crowded� for this printing, you can find the correct location on the �test point overviews� in this manual (chapter 6). A very large part of the LSP is 'hot', such as: � The primary part of the Standby Supply. � The whole Main supply (except for the secondary Audio supply). � And the complete deflection circuitry (so notice that the deflection coil is hot!!). 5.8.4

3. Via the �SUP-ENABLE� signal, the Main Supply is switched �on� and will deliver the VBAT to the Line deflection stage [2]. 4. EHT generation is now started. 5. The OTC will un-blank the picture. 6. When you switch �off� the set, this is done in a controlled way via the POR signal [3]. Note: Standby is not directly achieved via the Standby line of the microprocessor, but indirectly via the HOP circuitry. 5.8.3 ComPair This chassis does not have an IR transmitting LED (as in MGsets). Therefore, a �Service� (ComPair) connector is implemented at the rear side of the set, which is directly accessible (as in A10-, EM2E- and EM3E-sets). In addition to this, there is also a blinking LED procedure to show the contents of the error buffer. When you use ComPair, you have the possibility to activate a �stepwise start-up� mode. With this mode, you can initiate the start-up sequence step by step. This also means that in certain steps, some protections are not activated. This is sometimes very convenient during repair (see also paragraph 5.4.3). Protections There are �service pads� implemented on the SSB (items 9005 and 9006, outside the shielding), to force the set in SAM or SDM (see also figure: �SSB removal (part 3)� in Chapter 4). This will overrule the processor-controlled protections, but not the hardware protections. This means, that the A/D-input protections (5 and 8 V) and the I2C �not-acknowledging� info of the feature box (FBX) and of the Tuner are overruled. Caution: When doing this, the service technician must know what he is doing, as it could lead to damaging the set. The �ARC�- and/or �BRIDGECOIL� protection are hardly ever triggered, however: When you suspect the �ARC� protection, look for bad solder joints and smell. By interrupting resistor 3497, this protection is disabled (special attention needed!). When you suspect the �BRIDGECOIL� protection, which can also be due to a too wide picture amplitude, shorten G and S of the E/W MOSFET 7480. This will disable the protection. You will now have minimal horizontal amplitude. Re-align the horizontal amplitude in the SAM menu and remove the G/S

5.8.2

Start-up Sequence
COLD HOT

EHT-INFO

8V 2 I C BUS 1

5 START/STOP 17/39 HOP 29 START/STOP OUT

5VCON RESET 106 8VCON 105 OTC 99 POR STANDBY low 7131/41 closed high 7131/41 open 3 7131 104 7141 5V 8V

CUTOFF (from CRT panel) 2

short of TS7480. 5.8.5
220 VAC

Main Supply The simplest way is, to replace the components of the Main Supply with repair kit (3122 785 90310) More detailed way: 1. Replace FET 7504 and zener 6505. 2. Remove the SSB panel. 3. Short B and E of TS7529, in order to put the Main Supply in �on�-mode (TS7529 is blocking then). Caution: To prevent that R3403 and TS7443 will be damaged, first disable the HW-protection of the deflection circuit. Therefore short circuit C2642 on the LSP (diagram A4). 4. Attach a load of 500 � to VBAT capacitor C2515 (the supply can not work without a minimum load). 5. Use a variac, and slowly increase the VMAINS. Measure over sensing resistors R3514//15 if a nice sawtooth voltage becomes available. 6. Also measure the VBAT. This may never exceed +141 V. If it does, there is something wrong in the feedback circuitry (e.g. regulator 7506). Note: Be careful when measuring on the gate of FET TS7504. This circuitry is very high ohmic and can easily be damaged

STBY SUPPLY

MAIN SUPPLY
Vbat

SUP-ENABLE

+11D POR 7445

LINE DEFL. (BRIDGECOIL -PROT) (ARC-PROT) PROTSENSING FRAME DEFL (NON-VFB)
CL16532044_023.eps 140501

Figure 5-3 Start-up circuitry The start up sequence differs from other sets (e.g. MG-sets or EM2E-sets, but is same as in EM3E-set): 1. When the set is switched �on�, the 5 and 8 V lines (�+5V_CON� and �+8V_CON�) of the standby power supply are activated. 2. After the OTC senses them, the µP will address the HOP via the I2C-bus, to start the drive [1].

Quizás también quiera comprar

$4.99

SX-K700 TECHNICS
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …

$4.99

CJ-V51 PIONEER
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

SX-PR602 TECHNICS
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

EV-S1000E SONY
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

AG7330 PANASONIC
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

EVO-9850 VOLUME 1 SONY
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…
>
Parse Time: 0.959 - Number of Queries: 128 - Query Time: 0.517